Comparative Assessment of HVDC Systems for Connecting Renewable Energy Sources to Urban Load Centers

Authors

  • Xinyuan Li Beijing National Day School, Beijing, China

DOI:

https://doi.org/10.62051/1za99c56

Keywords:

HVDC; LCC; VSC; MMC; Renewable energy.

Abstract

This paper assesses the various high voltage direct current (HVDC) systems and topologies' suitability for connecting renewable energy sources with urban load centers in various geographical and pre-existing grid conditions. The three representative cases analyzed are the offshore wind connection of BorWin1 in Germany, the multi-terminal Zhangbei HVDC grid in which renewable energy generation is connected to multiple population centers and the ultra-high-voltage direct current (UHVDC) connection of Zhundong, which connects renewable generation with population centers in the middle of the country. There are several criteria that are assessed in the comparison: transmission capacity, distance, efficiency, voltage-control capabilities, protection against faults, offshore/onshore suitability, multi-terminal capability, renewable energy integration, expandability and economic factors in cases where reliable data are available. The paper finds that in a weaker grid or offshore connection, the flexibility required for an electrically weak existing AC system is provided by the Voltage-Source Converter (VSC) system, whereas in very high capacity and long-distance bulk transmission, the Line-Commutated Converter (LCC) type of HVDC systems is advantageous. With several renewable energy generation sources, storage plants, and load centers to exchange power, Multi-Terminal HVDC (MTDC) using Modular Multilevel Converter (MMC) can offer greater flexibility. Overall, it can be concluded that, contrary to the assumption that one converter technology is superior to the other, the choice of the converter technology best suited for a particular situation depends on the given circumstances.

Downloads

Download data is not yet available.

References

[1] Wang W., Li G., Guo J. Large-scale renewable energy transmission by HVDC: challenges and proposals. Engineering, 2022, 19(12): 252-267.

[2] Chandio R.H., Chachar F.A., Soomro J.B., Ansari J.A., Munir H.M., Zawbaa H.M., Kamel S. Control and protection of MMC-based HVDC systems: a review. Energy Reports, 2023, 9: 1571-1588.

[3] Mitra B., Chowdhury B., Manjrekar M. HVDC transmission for access to offshore renewable energy: a review of technology and fault detection techniques. IET Renewable Power Generation, 2018.

[4] Wang M., An T., Ergun H., Lan Y., Andersen B., Szechtman M., Leterme W., Beerten J., Van Hertem D. Review and outlook of HVDC grids as backbone of the transmission system. CSEE Journal of Power and Energy Systems, 2021, 7(4): 797-810.

[5] Ye H., Li J., He M., Du Y., Liu H. Power shift-based optimal corrective control for bipolar multi-terminal high-voltage direct current grid. IET Generation, Transmission & Distribution, 2019, 13(13): 2711-2720.

[6] Alassi A., Bañales S., Ellabban O., Adam G., MacIver C. HVDC transmission: technology review, market trends and future outlook. Renewable and Sustainable Energy Reviews, 2019, 112: 530-554.

[7] Taherzadeh E., Radmanesh H., Javadi S., Gharehpetian G.B. Circuit breakers in HVDC systems: state-of-the-art review and future trends. Protection and Control of Modern Power Systems, 2023, 8: 38.

[8] Sahebkar Farkhani J., Çelik Ö., Ma K., Bak C.L., Chen Z. A comprehensive review of potential protection methods for VSC multi-terminal HVDC systems. Renewable and Sustainable Energy Reviews, 2024, 192: 114280.

[9] Deng J., Cheng F., Yao L., Xu J., Mao B., Li X., Chen R. A review of system topologies, key operation and control technologies for offshore wind power transmission based on HVDC. IET Generation, Transmission & Distribution, 2023, 17(15): 3345-3363.

[10] Barberis Negra N., Todorovic J., Ackermann T. Loss evaluation of HVAC and HVDC transmission solutions for large offshore wind farms. Electric Power Systems Research, 2006, 76(11): 916-927.

[11] Zhong J., Qi Q., He H., He H., Ding T., He J. Study on characteristics of slow-front overvoltage of ±1100 kV UHVDC transmission lines. The Journal of Engineering, 2019: 1726-1729.

[12] Wang X., Meng P., Wen J. Development and advances in modular multilevel converter based HVDC projects in China. Frontiers of Engineering Management, 2023, 10(1): 183-189.

[13] Wang Y., Zhang B., Fan X. The overhead transmission line protection scheme for the voltage-source converter-based HVDC grids. The Journal of Engineering, 2019: 674-679.

Downloads

Published

22-11-2026