Performance Trade-Off Analysis of Low-Power Wearable ECG Analog Front Ends

Authors

  • Haoxiang Sun Performance Trade-Off Analysis of Low-Power Wearable ECG Analog Front Ends

DOI:

https://doi.org/10.62051/2m50r432

Keywords:

Wearable ECG; Analog Front-End; Operational Amplifier; Low Power; Input-Referred Noise.

Abstract

Wearable electrocardiogram (ECG) devices need analog front-end (AFE) circuits that can detect microvolt-to-millivolt cardiac signals continuously for extended periods with very small batteries or harvested energy. The first amplification stage strongly influences total input-referred noise and therefore requires careful allocation of the power budget. This paper studies the engineering trade-off between input-referred noise and power consumption in low-power operational-amplifier-based ECG AFEs. This comparative literature review examines peer-reviewed designs published from 2015 to 2026 and draws on established work on chopper stabilization, auto-zero techniques, common-mode interference and wearable biosensing. The comparison includes power, integrated input-referred noise, gain, bandwidth, common-mode rejection ratio, input impedance and noise efficiency where reported. The results show that there is no single universally optimal AFE; the lowest-power designs reviewed here accept higher noise, and sub-microvolt noise generally requires microwatt-level power or more advanced circuit techniques. Chopper stabilization, current reuse, weak-inversion biasing, capacitive coupling and digitally assisted offset cancellation can be used to shift this trade-off, but each has its own disadvantages, such as ripple, reduced input impedance, bandwidth limitations, area or circuit complexity. Therefore, future wearable ECG AFEs should focus on adaptive, application-specific biasing and standardized multi-metric benchmarking rather than solely reducing power consumption or noise.

Downloads

Download data is not yet available.

References

[1] Wang S., Yang H., Jiao G., et al. ECG analog front end circuit—A review. Measurement, 2026, 267: 120566. DOI: 10.1016/j.measurement.2026.120566. DOI: https://doi.org/10.1016/j.measurement.2026.120566

[2] Pantelopoulos A., Bourbakis N. G. A survey on wearable biosensor systems for health monitoring. In: 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 2008: 4887-4890. DOI: 10.1109/IEMBS.2008.4650309. DOI: https://doi.org/10.1109/IEMBS.2008.4650309

[3] Sadeghi M., Yavari M. A CMOS analog front-end with high CMRR and large DC offset rejection, along with a novel chopper spike filter for wireless wearable ECG sensors. AEU - International Journal of Electronics and Communications, 2026, 212: 156282. DOI: 10.1016/j.aeue.2026.156282. DOI: https://doi.org/10.1016/j.aeue.2026.156282

[4] Fernández-Chimeno M., Pallàs-Areny R. A comprehensive model for power line interference in biopotential measurements. IEEE Transactions on Instrumentation and Measurement, 2000, 49(3): 535-540. DOI: 10.1109/19.850390. DOI: https://doi.org/10.1109/19.850390

[5] Zhang J., Guo Y., Dong X., et al. Opportunities and challenges of noise interference suppression algorithms for dynamic ECG signals in wearable devices: A review. Measurement, 2025, 250: 117067. DOI: 10.1016/j.measurement.2025.117067. DOI: https://doi.org/10.1016/j.measurement.2025.117067

[6] Song S., Rooijakkers M., Harpe P., et al. A low-voltage chopper-stabilized amplifier for fetal ECG monitoring with a 1.41 power efficiency factor. IEEE Transactions on Biomedical Circuits and Systems, 2015, 9(2): 237-247. DOI: 10.1109/TBCAS.2015.2417124. DOI: https://doi.org/10.1109/TBCAS.2015.2417124

[7] Bai W., Zhu Z. A 0.5-V power-efficient low-noise CMOS instrumentation amplifier for wireless biosensor. Microelectronics Journal, 2016, 51: 30-37. DOI: 10.1016/j.mejo.2016.02.007. DOI: https://doi.org/10.1016/j.mejo.2016.02.007

[8] Enz C. C., Temes G. C. Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilization. Proceedings of the IEEE, 1996, 84(11): 1584-1614. DOI: 10.1109/5.542410. DOI: https://doi.org/10.1109/5.542410

[9] Yang W., Jiang H., Yin Y., et al. A 4-µW analog front end achieving 2.4 NEF for long-term ECG monitoring. IEEE Transactions on Biomedical Circuits and Systems, 2021, 15(4): 655-665. DOI: 10.1109/TBCAS.2021.3084152. DOI: https://doi.org/10.1109/TBCAS.2021.3084152

[10] Han W., Yu Q., Wu K., et al. A programmable analog front-end with independent biasing technique for ECG signal acquisition. Microelectronics Journal, 2023, 136: 105792. DOI: 10.1016/j.mejo.2023.105792. DOI: https://doi.org/10.1016/j.mejo.2023.105792

[11] Harpe P. J. A., Gao H., van Dommele A. R., et al. A 0.20 mm² 3 nW signal acquisition IC for miniature sensor nodes in 65 nm CMOS. IEEE Journal of Solid-State Circuits, 2016, 51(1): 240-248. DOI: 10.1109/JSSC.2015.2487270. DOI: https://doi.org/10.1109/JSSC.2015.2487270

[12] Kosari A., Breiholz J., Liu N., et al. A 0.5 V 68 nW ECG monitoring analog front-end for arrhythmia diagnosis. Journal of Low Power Electronics and Applications, 2018, 8(3): 27. DOI: 10.3390/jlpea8030027. DOI: https://doi.org/10.3390/jlpea8030027

[13] Ding J., Tang Y., Zhang L., et al. A novel front-end design for bioelectrical signal wearable acquisition. IEEE Sensors Journal, 2019, 19(18): 8009-8018. DOI: 10.1109/JSEN.2019.2917938. DOI: https://doi.org/10.1109/JSEN.2019.2917938

Downloads

Published

23-11-2026